TXXI-IK & RL 0,6/1kV

Products

TXXI IK 0,6/1 kV 4G25 mm² AFR

Nexans ref. 10556893 - Country ref. 1007475

  • Packaging: Drum (1000m)
  • Conductor cross-section: 25 mm²
  • Number of cores: 4
  • Nominal outer diameter: 24.0 mm
  • Approximate weight: 0.5 kg/m
  • Permissible current rating in open air: 105 A
  • Permissible current rating when buried: 125 A
  • Zero sequence resistance at 20°C: 4.8 Ohm/km
  • Capacity of phase cores approx.: 0.07 µF / km
  • Maximum Pulling Tension: 3 kN

TXXI IK 0,6/1 kV 4G50 mm² AFR

Nexans ref. 10556895 - Country ref. 1007476

  • Packaging: Drum (1000m)
  • Conductor cross-section: 50 mm²
  • Number of cores: 4
  • Nominal outer diameter: 31.0 mm
  • Approximate weight: 0.9 kg/m
  • Permissible current rating in open air: 165 A
  • Permissible current rating when buried: 180 A
  • Zero sequence resistance at 20°C: 2.56 Ohm/km
  • Capacity of phase cores approx.: 0.08 µF / km
  • Maximum Pulling Tension: 6 kN

TXXI IK 0,6/1 kV 4G95 mm² AFR NEW

Nexans ref. 10564534 - Country ref. 1007461

  • Packaging: Drum (1000m)
  • Conductor cross-section: 95 mm²
  • Number of cores: 4
  • Nominal outer diameter: 40.5 mm
  • Approximate weight: 1.6 kg/m
  • Permissible current rating in open air: 245 A
  • Permissible current rating when buried: 260 A
  • Zero sequence resistance at 20°C: 1.28 Ohm/km
  • Capacity of phase cores approx.: 0.09 µF / km
  • Maximum Pulling Tension: 11.4 kN

TXXI IK 0,6/1 kV 4G150 mm² AFR NEW

Nexans ref. 10564535 - Country ref. 1007463

  • Packaging: Drum (1000m)
  • Conductor cross-section: 150 mm²
  • Number of cores: 4
  • Nominal outer diameter: 49.5 mm
  • Approximate weight: 2.4 kg/m
  • Permissible current rating in open air: 320 A
  • Permissible current rating when buried: 335 A
  • Zero sequence resistance at 20°C: 0.824 Ohm/km
  • Capacity of phase cores approx.: 0.09 µF / km
  • Maximum Pulling Tension: 18 kN

TXXI IK 0,6/1 kV 4G240 mm² AFR NEW

Nexans ref. 10564536 - Country ref. 1007465

  • Packaging: Drum (1000m)
  • Conductor cross-section: 240 mm²
  • Number of cores: 4
  • Nominal outer diameter: 62.7 mm
  • Approximate weight: 3.9 kg/m
  • Permissible current rating in open air: 430 A
  • Permissible current rating when buried: 435 A
  • Zero sequence resistance at 20°C: 0.5 Ohm/km
  • Capacity of phase cores approx.: 0.1 µF / km
  • Maximum Pulling Tension: 28.8 kN

TXXI-RL 0,6/1 kV 5G25 mm² AFR

Nexans ref. 10546591 - Country ref. 1007485

  • Packaging: Drum (1000m)
  • Conductor cross-section: 25 mm²
  • Number of cores: 5
  • Nominal outer diameter: 27.0 mm
  • Approximate weight: 0.7 kg/m
  • Permissible current rating in open air: 105 A
  • Permissible current rating when buried: 125 A
  • Zero sequence resistance at 20°C: 4.8 Ohm/km
  • Capacity of phase cores approx.: 0.09 µF / km
  • Maximum Pulling Tension: 3.75 kN

TXXI-RL 0,6/1 kV 5G50 mm² AFR

Nexans ref. 10546593 - Country ref. 1007486

  • Packaging: Drum (1000m)
  • Conductor cross-section: 50 mm²
  • Number of cores: 5
  • Nominal outer diameter: 36.0 mm
  • Approximate weight: 1.1 kg/m
  • Permissible current rating in open air: 165 A
  • Permissible current rating when buried: 180 A
  • Zero sequence resistance at 20°C: 2.56 Ohm/km
  • Capacity of phase cores approx.: 0.1 µF / km
  • Maximum Pulling Tension: 7.5 kN

Description

Description

Standards

  • International
    EN 50267-2-1; EN 50267-2-2; EN 50268-2; HD 603.5J; IEC 60228; IEC 60332-1-2; IEC 60754-1; IEC 60754-2; IEC 61034
  • National
    NEK 536

Power distribution cable, designated for road lights, entry point installation or other general outdoor use (UV-resistant).

The cable is fire-retardant and halogen free, each phase having insulation and an outer sheath.

Can be placed directly in soil.

When laying at a lower temperatures than 0 degrees Celsius, care must be taken to avoid damage to the outer sheath. It is especially important that the cable is not exposed to impact at temperatures below 0  °C.

When laying at lower temperatures than -10 degrees Celsius, the cable should be preheated before laying as well.

If the cable is cut and not installed immediately, each phase must be sealed, to prevent water intrusion.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Stranded class 2
Conductor shape
Round, stranded

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close