LANmark-OF Slimflex Patch Cords OM3

Produkter

LANmark-OF Slimflex Patch Cord DLC-DLC OM3 LSZH Xm Aqua

Nexans art.nr. N122.5LLAX

  • Konnektor type: Duplex LC-LC

 

LANmark-OF Slimflex Patch Cord DSC-DLC OM3 LSZH Xm Aqua

Nexans art.nr. N122.5CLAX

  • Konnektor type: Duplex SC-LC

 

LANmark-OF Slimflex Patch Cord DSC-DSC OM3 LSZH Xm Aqua

Nexans art.nr. N122.5CCAX

  • Konnektor type: Duplex SC-SC

 

Beskrivelse

Beskrivelse

Standarder

  • Internasjonal
    ISO/IEC 11801

Guarantees and installation
Nexans LANmark-OF optical fibre patch cords have been designed for indoor applications in support of high speed protocols.
High speed protocols supported include, but are not limited to

  • Ethernet: 1GBase-SX, 10GBase-SR, 25GBASE-SR
  • Fibre channel Serial: 4G, 8G, 16G and 32G

Details on the supported distances can be found in the LANmark-OF warranty modules.

 

Typical installation environments are:

  • Cabinets to connect patch panels to active equipment.
  • Cross connects in data centres.
  • Suitable for use in the work area to connect the workstation to the wall outlet (Fibre To The Desk).

 

Characteristics

  • Patch cord cable is according to IEC 60794-2-50
  • Maximum insertion loss according to IEC 61300-3-4: 0.25 dB
  • Typical insertion loss: 0.1 dB
  • Minimum return loss according to IEC 61300-3-6: 30 dB
  • Duplex LC-LC, duplex LC-SC and duplex SC-SC patch cords have a duplex cable construction with a diameter of 2 X 2.0 mm.
  • Short connector boots of 19mm
  • Small bend radius: 10 mm
  • A label is added close to the duplex connector for traceability of the measurement results 

 

Fibre

The LANmark-OF OM3 patch cords have LANmark-OF OM3 GIGAliteFLEX fibre inside.  This bend insensitive multimode fibre has a small bend radius and is compliant to IEC 60793-2-10, fibre model A1a.2b. 

 

Design
Nexans LANmark-OF patch cords designed according to the "Cross-Over" wiring principle to improve field installation (A1-B2, B1-A2). This conforms to the requirements of IEC 11801 and EN 50174-1:2009.

The "butterfly" duplex clip allows to change the polarity on site easily by simply removing the 2 connectors and put them in a reverse order back into the same clip. No tool is required for this polarity change.

Schematic Polarity Duplex Patch Cord

Karakteristikker

Karakteristikker

Konstruksjonsegenskaper

Konstruksjonsegenskaper

Farge
Aqua
Fibertype
OM3 50/125
Skjerm/-armeringstype
Aramidgarn
Ytre kappe
LSZH-FR

Transmisjonsegenskaper

Transmisjonsegenskaper

Insertion Loss, maximum, dB
0,25 dB
Return Loss, Minimum, dB
30 dB

Mekaniske egenskaper

Mekaniske egenskaper

Maximum pulling force (IEC 60794-1-2-E1)
200 N
Motstand mot sammenpressing (IEC 794-1)
100 N/cm

Bruksegenskaper

Bruksegenskaper

Driftstemperatur område
-10 ... 50 °C
Min. statisk bøyeradius
10 mm

Ressurser

Ressurser

Kontakt oss

Tema som du ønsker mer informasjon om:

Påkrevde felter*

Vennligst sjekk det du har lagt inn for feil

E-postadresse må inneholde @ tegnet

Personlig databeskytter

Det er din rett å nekte behandling og analyse av dine personlige data, og deres bruk til markedsføringsformål

Tusen takk!

Takk for at du kontaktet oss, vi tar kontakt med deg snarlig.

Feil

En feil har skjedd. Vennligst prøve igjen.

Lukk