TSLI 12kV til 36 kV single core

Products

TSL I24kV 1x630AQ

Nexans ref. 10202732 - Country ref. 1017529

  • Conductor flexibility: Class 2
  • Conductor cross-section: 630 mm²
  • Number of cores: 1
  • Maximum operating voltage: 24 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

TSLI 12kV 1x 50AQ

Nexans ref. 10071395 - Country ref. 1017520

  • Conductor flexibility: Stranded class 2
  • Conductor cross-section: 50 mm²
  • Number of cores: 1
  • Maximum operating voltage: 12 kV
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

TSLI 12kV 1x240AQ

Nexans ref. 10071394

  • Conductor flexibility: Class 2
  • Conductor cross-section: 240 mm²
  • Number of cores: 1
  • Maximum operating voltage: 12 kV
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

TSLI 12kV 1x630AQ

Nexans ref. 10227777 - Country ref. 1017522

  • Conductor flexibility: Class 2
  • Conductor cross-section: 630 mm²
  • Number of cores: 1
  • Maximum operating voltage: 12 kV
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

TSLI 24kV 1x 50AQ

Nexans ref. 10202731 - Country ref. 1017524

  • Conductor flexibility: Class 2
  • Conductor cross-section: 50 mm²
  • Number of cores: 1
  • Maximum operating voltage: 24 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

TSLI 24kV 1x 95AQ

Nexans ref. 10218072 - Country ref. 1017525

  • Conductor flexibility: Class 2
  • Conductor cross-section: 95 mm²
  • Number of cores: 1
  • Maximum operating voltage: 24 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

TSLI 24kV 1x150AQ

Nexans ref. 10071397 - Country ref. 1017526

  • Conductor flexibility: Class 2
  • Conductor cross-section: 150 mm²
  • Number of cores: 1
  • Maximum operating voltage: 24 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

TSLI 24kV 1x240A

Nexans ref.

  • Conductor flexibility: Class 2
  • Conductor cross-section: - mm²
  • Number of cores: -
  • Maximum operating voltage: - kV
  • Rated Voltage Uo/U (Um):

 

TSLI 24kV 1x240AQ

Nexans ref. 10251789 - Country ref. 1017527

  • Conductor flexibility: Class 2
  • Conductor cross-section: 240 mm²
  • Number of cores: 1
  • Maximum operating voltage: 24 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

TSLI 24kV 1x400AQ

Nexans ref. 10203265 - Country ref. 1017528

  • Conductor flexibility: Class 2
  • Conductor cross-section: 400 mm²
  • Number of cores: 1
  • Maximum operating voltage: 24 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

TSLI 36kV 1x150AQ

Nexans ref. 10265007

  • Conductor flexibility: Class 2
  • Conductor cross-section: 150 mm²
  • Number of cores: 1
  • Maximum operating voltage: 36 kV
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

TSLI 36kV 1x400A/35

Nexans ref. 10275611

  • Conductor flexibility: Class 2
  • Conductor cross-section: 400 mm²
  • Number of cores: 1
  • Maximum operating voltage: 36 kV
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

TSLI 36kV 1x400AQ

Nexans ref. 10243556

  • Conductor flexibility: Class 2
  • Conductor cross-section: 400 mm²
  • Number of cores: 1
  • Maximum operating voltage: 36 kV
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

TSLI 36kV 1x630AQ

Nexans ref. 10265197

  • Conductor flexibility: Class 2
  • Conductor cross-section: 630 mm²
  • Number of cores: 1
  • Maximum operating voltage: 36 kV
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

TSLI12kV1x150AQ

Nexans ref.

  • Conductor flexibility: Class 2
  • Conductor cross-section: 150 mm²
  • Number of cores: 1
  • Maximum operating voltage: 12 kV
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

TSLI12kV1x400AQ

Nexans ref.

  • Conductor flexibility: Stranded class 5
  • Conductor cross-section: 400 mm²
  • Number of cores: 1
  • Maximum operating voltage: 12 kV
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

TSLI36kV1x240AQ

Nexans ref.

  • Conductor flexibility: Class 2
  • Conductor cross-section: 240 mm²
  • Number of cores: 1
  • Maximum operating voltage: 36 kV
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

Description

Description

Standards

  • Product
    HD 620.10K
  • Test
    IEC 60332-3 Cat.C

User benefits

  • Diffusion free high voltage cable
  • Avoids threfore growth of watertrees in the XLPE insulation which increases the lifetime.
  • Outer sheath of fire retardant material
  • Meter marks

Application

  • Indoor
  • Tunnels
  • Industrial installations
  • Surroundings which require a fire retardent cable

Fire properties

  • Fire retardent
  • Halogenfree

Characteristics

Characteristics

Resources

Resources

Selling & delivery Information

Cable marking:

NEXANS NS TSLI XX kV 1 x mm²/mm² MONTH YEAR, metermarks

Lifemark

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close