G12/T12 G652D/G657A1 QXXE Ultimate™

Description

Description

Standards

  • International
    IEC 60793; IEC 60794; ITU-T Rec. G.650; ITU-T Rec. G.652

The cable type is longitudinally water-blocked and intended for outdoor use (in ducts). The design can incorporate 12 to 288 fibres in loose tubes. The individually coloured fibres are tubed in groups of maximum 12 or 24 and stranded onto a central dielectric fibre reinforced strength member (FRP). The cable type is longitudinal water-blocked through the use of swellable yarn and sheathed with halogen-free black polyethylene.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Construction type
Loose tube, SZ
Fiber optic type
SingleMode 9/125
Type of secondary protection
Loose tube
Outer sheath
PE-HD
Sheath colour
Black
Material used for longitudinal water tightness
Swellable yarn
Halogen free
Yes
Metal free
Yes
Length water tightness Tube
Vaseline
Number of tube layer 1
6
Strength member
Central FRP

Dimensional characteristics

Dimensional characteristics

Number of optical fibres, range
2 ... 288
Number of optical fibres
12
Average sheath thickness
0.4 mm
Approximate weight
30 kg/km
Central strength member size
1.7 mm
Diameter over assembly
5.0 mm
Max. number of fibres per tube
12
Nominal outer diameter
5.8 mm
Tube diameter
1.6 mm

Mechanical characteristics

Mechanical characteristics

Maximum pulling force by laying
0.6 kN
Maximum permanent tensile load
0.25 kN
Crush resistance (EN 187 000)
1 kN
Impact resistance (EN 187 000)
5 J

Usage characteristics

Usage characteristics

Installation type
Outdoor - Duct
Operating temperature, range
-40 ... 70 °C
Ambient installation temperature, range
-15 ... 50 °C
Storage temperature, range
-40 ... 70 °C
Bending factor when installed
10 (xD)
Dynamic bending factor
15 (xD)

Resources

Resources

Selling & delivery Information

The outer sheath of the cable is marked with cable type, manufacturer, identification number and meter marking.
The cable is delivered on wooden recyclable drums in lengths according to arrangement. The drum is marked with the cable type, length, rolling direction and installation information. Cable ends closed with end cap.

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close