PTS LSZH 0,6mm skjermet signal/alarm parkabel

Products

2 par 0,6 PTS HF (1x4) B2 350

Nexans ref. 10195814 - Country ref. 1008149

  • Packaging: Box (350m)
  • Number of pairs: 2
  • Nominal outer diameter: 4.1 mm
  • Approximate weight: 27 kg/km
  • Max. DC resistance of the conductor at 20°C: 64 Ohm/km
  • Max. capacity pair / core to core: 74 nF/km
  • Ohmical resistance of the insulation: 499 MOhm.km
  • Length: 350 m

 

2 par 0,6 PTS HF (1x4) B1 150

Nexans ref. 10195819 - Country ref. 1008150

  • Packaging: Reel in a box (150m)
  • Number of pairs: 2
  • Nominal outer diameter: 4.1 mm
  • Approximate weight: 27 kg/km
  • Max. DC resistance of the conductor at 20°C: 65 Ohm/km
  • Max. capacity pair / core to core: 75 nF/km
  • Ohmical resistance of the insulation: 500 MOhm.km
  • Length: 150 m

 

4 par 0,6 PTS HF E4 750

Nexans ref. 10195815 - Country ref. 1008151

  • Packaging: Drum (m)
  • Number of pairs: 4
  • Nominal outer diameter: 6.0 mm
  • Approximate weight: 46 kg/km
  • Max. DC resistance of the conductor at 20°C: 65 Ohm/km
  • Max. capacity pair / core to core: 75 nF/km
  • Ohmical resistance of the insulation: 500 MOhm.km
  • Length: 750 m

 

4 par 0,6 PTS HF B2 130

Nexans ref. 10195820 - Country ref. 1008152

  • Packaging: Box (130m)
  • Number of pairs: 4
  • Nominal outer diameter: 6.0 mm
  • Approximate weight: 46 kg/km
  • Max. DC resistance of the conductor at 20°C: 65 Ohm/km
  • Max. capacity pair / core to core: 75 nF/km
  • Ohmical resistance of the insulation: 500 MOhm.km
  • Length: 130 m

 

6 par 0,6 PTS HF E4 500

Nexans ref. 10195816 - Country ref. 1008153

  • Packaging: Drum (m)
  • Number of pairs: 6
  • Nominal outer diameter: 7.0 mm
  • Approximate weight: 61 kg/km
  • Max. DC resistance of the conductor at 20°C: 65 Ohm/km
  • Max. capacity pair / core to core: 75 nF/km
  • Ohmical resistance of the insulation: 500 MOhm.km
  • Length: 500 m

 

6 par 0,6 PTS HF B2 130

Nexans ref. 10195821 - Country ref. 1008154

  • Packaging: Box (130m)
  • Number of pairs: 6
  • Nominal outer diameter: 7.0 mm
  • Approximate weight: 61 kg/km
  • Max. DC resistance of the conductor at 20°C: 65 Ohm/km
  • Max. capacity pair / core to core: 75 nF/km
  • Ohmical resistance of the insulation: 500 MOhm.km
  • Length: 130 m

 

10 par 0,6 PTS HF E4 350

Nexans ref. 10195817 - Country ref. 1008155

  • Packaging: Drum (m)
  • Number of pairs: 10
  • Nominal outer diameter: 8.7 mm
  • Approximate weight: 95 kg/km
  • Max. DC resistance of the conductor at 20°C: 65 Ohm/km
  • Max. capacity pair / core to core: 75 nF/km
  • Ohmical resistance of the insulation: 500 MOhm.km
  • Length: 350 m

 

10 par 0,6 PTS HF B2 90

Nexans ref. 10195822 - Country ref. 1008156

  • Packaging: Box (90m)
  • Number of pairs: 10
  • Nominal outer diameter: 8.7 mm
  • Approximate weight: 95 kg/km
  • Max. DC resistance of the conductor at 20°C: 65 Ohm/km
  • Max. capacity pair / core to core: 75 nF/km
  • Ohmical resistance of the insulation: 500 MOhm.km
  • Length: 90 m

 

20 par 0,6 PTS HF E4 200

Nexans ref. 10195818 - Country ref. 1008157

  • Packaging: Drum (m)
  • Number of pairs: 20
  • Nominal outer diameter: 8.8 mm
  • Approximate weight: 172 kg/km
  • Max. DC resistance of the conductor at 20°C: 65 Ohm/km
  • Max. capacity pair / core to core: 75 nF/km
  • Ohmical resistance of the insulation: 500 MOhm.km
  • Length: 200 m

 

Description

Description

Standards

  • Test
    IEC 60332-1; IEC 60754; IEC 61034

CONSTRUCTION

1. Conductors

Single tinned annealed cooper wire, diameter of 0,6 mm.

2. Insulation

Coloured PE, nom. average thickness is 0,20 mm.

3. Twisting

Insulated conductors twisted in to the pairs.

4. Built-up

PE insulated Cu wire, twisted conductors in a pair, cables with more then 5 pairs are banded with PETP foil, halogen free sheath type HFFR-LS.

5. Screen

Lengthwise Al/PETP tape, beneath the tape, there is one lengthwise tinned drain wire 0,5 mm.

QUALITY AND ENVIRONMENTAL SYSTEM

Construction, production and testing are made according to ISO 9001 and 14001.

Characteristics

Characteristics

Dimensional characteristics

Dimensional characteristics

Average insulation thickness
0.2 mm
Conductor diameter
0.6 mm

Electrical characteristics

Electrical characteristics

Capacitance unbalance pair to pair
990 pF/km
Nominal resistance of the conductor
61.00 Ohm/km

Usage characteristics

Usage characteristics

Ambient installation temperature, range
-10 ... 40 °C
Operating temperature, range
-15 ... 70 °C

Resources

Resources

Documentation

Farveskema pdf — 34.3 kB

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close