- Products
- Segments
- Newsroom
- Tools and Resources
- Sustainability
- We are Nexans
- Search
- Contact us
- Compare
- Sign in
PTS LSZH 0,6mm skjermet signal/alarm parkabel
PTS LSZH 0,6mm skjermet signal/alarm parkabel
Telecom indoor installation HFFR-LS cable with a screen intended for use in phone and control plants.
Read more2 par 0,6 PTS HF (1x4) B2 350
Nexans ref. 10195814 - Country ref. 1008149
- Packaging: Box (350m)
- Number of pairs: 2
- Nominal outer diameter: 4.1 mm
- Approximate weight: 27 kg/km
- Max. DC resistance of the conductor at 20°C: 64 Ohm/km
- Max. capacity pair / core to core: 74 nF/km
- Ohmical resistance of the insulation: 499 MOhm.km
- Length: 350 m
2 par 0,6 PTS HF (1x4) B1 150
Nexans ref. 10195819 - Country ref. 1008150
- Packaging: Reel in a box (150m)
- Number of pairs: 2
- Nominal outer diameter: 4.1 mm
- Approximate weight: 27 kg/km
- Max. DC resistance of the conductor at 20°C: 65 Ohm/km
- Max. capacity pair / core to core: 75 nF/km
- Ohmical resistance of the insulation: 500 MOhm.km
- Length: 150 m
4 par 0,6 PTS HF E4 750
Nexans ref. 10195815 - Country ref. 1008151
- Packaging: Drum (m)
- Number of pairs: 4
- Nominal outer diameter: 6.0 mm
- Approximate weight: 46 kg/km
- Max. DC resistance of the conductor at 20°C: 65 Ohm/km
- Max. capacity pair / core to core: 75 nF/km
- Ohmical resistance of the insulation: 500 MOhm.km
- Length: 750 m
4 par 0,6 PTS HF B2 130
Nexans ref. 10195820 - Country ref. 1008152
- Packaging: Box (130m)
- Number of pairs: 4
- Nominal outer diameter: 6.0 mm
- Approximate weight: 46 kg/km
- Max. DC resistance of the conductor at 20°C: 65 Ohm/km
- Max. capacity pair / core to core: 75 nF/km
- Ohmical resistance of the insulation: 500 MOhm.km
- Length: 130 m
6 par 0,6 PTS HF E4 500
Nexans ref. 10195816 - Country ref. 1008153
- Packaging: Drum (m)
- Number of pairs: 6
- Nominal outer diameter: 7.0 mm
- Approximate weight: 61 kg/km
- Max. DC resistance of the conductor at 20°C: 65 Ohm/km
- Max. capacity pair / core to core: 75 nF/km
- Ohmical resistance of the insulation: 500 MOhm.km
- Length: 500 m
6 par 0,6 PTS HF B2 130
Nexans ref. 10195821 - Country ref. 1008154
- Packaging: Box (130m)
- Number of pairs: 6
- Nominal outer diameter: 7.0 mm
- Approximate weight: 61 kg/km
- Max. DC resistance of the conductor at 20°C: 65 Ohm/km
- Max. capacity pair / core to core: 75 nF/km
- Ohmical resistance of the insulation: 500 MOhm.km
- Length: 130 m
10 par 0,6 PTS HF E4 350
Nexans ref. 10195817 - Country ref. 1008155
- Packaging: Drum (m)
- Number of pairs: 10
- Nominal outer diameter: 8.7 mm
- Approximate weight: 95 kg/km
- Max. DC resistance of the conductor at 20°C: 65 Ohm/km
- Max. capacity pair / core to core: 75 nF/km
- Ohmical resistance of the insulation: 500 MOhm.km
- Length: 350 m
10 par 0,6 PTS HF B2 90
Nexans ref. 10195822 - Country ref. 1008156
- Packaging: Box (90m)
- Number of pairs: 10
- Nominal outer diameter: 8.7 mm
- Approximate weight: 95 kg/km
- Max. DC resistance of the conductor at 20°C: 65 Ohm/km
- Max. capacity pair / core to core: 75 nF/km
- Ohmical resistance of the insulation: 500 MOhm.km
- Length: 90 m
20 par 0,6 PTS HF E4 200
Nexans ref. 10195818 - Country ref. 1008157
- Packaging: Drum (m)
- Number of pairs: 20
- Nominal outer diameter: 8.8 mm
- Approximate weight: 172 kg/km
- Max. DC resistance of the conductor at 20°C: 65 Ohm/km
- Max. capacity pair / core to core: 75 nF/km
- Ohmical resistance of the insulation: 500 MOhm.km
- Length: 200 m
Description
Description
Standards
-
TestIEC 60332-1; IEC 60754; IEC 61034
CONSTRUCTION
1. Conductors
Single tinned annealed cooper wire, diameter of 0,6 mm.
2. Insulation
Coloured PE, nom. average thickness is 0,20 mm.
3. Twisting
Insulated conductors twisted in to the pairs.
4. Built-up
PE insulated Cu wire, twisted conductors in a pair, cables with more then 5 pairs are banded with PETP foil, halogen free sheath type HFFR-LS.
5. Screen
Lengthwise Al/PETP tape, beneath the tape, there is one lengthwise tinned drain wire 0,5 mm.
QUALITY AND ENVIRONMENTAL SYSTEM
Construction, production and testing are made according to ISO 9001 and 14001.
Characteristics
Characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania