LiYCY 300/500V (CPR)

Products

LiYCY 10 x 0,50

Nexans ref. 10263243 - Country ref. 1005655

  • Packaging: Drum (1000m)
  • Approximate weight: 122 kg/km
  • Outer Diameter: 8.8 mm
  • Conductor cross-section: 0.5 mm²
  • Number of cores: 10

 

LiYCY 12 x 0,75

Nexans ref. 10263260 - Country ref. 1005673

  • Packaging: Drum (1000m)
  • Approximate weight: 187 kg/km
  • Outer Diameter: 10.4 mm
  • Conductor cross-section: 0.75 mm²
  • Number of cores: 12

 

LiYCY 18 x 0,50

Nexans ref. 10264850 - Country ref. 1005658

  • Packaging: Drum (1000m)
  • Approximate weight: 196 kg/km
  • Outer Diameter: 11 mm
  • Conductor cross-section: 0.5 mm²
  • Number of cores: 18

 

LiYCY 2 x 0,50

Nexans ref. 10567412 - Country ref. 1005648

  • Packaging: Drum (1000m)
  • Approximate weight: 38 kg/km
  • Outer Diameter: 5.1 mm
  • Conductor cross-section: 0.5 mm²
  • Number of cores: 2

 

LiYCY 2 x 0,75

Nexans ref. 10263254 - Country ref. 1005665

  • Packaging: Drum (1000m)
  • Approximate weight: 46 kg/km
  • Outer Diameter: 5.7 mm
  • Conductor cross-section: 0.75 mm²
  • Number of cores: 2

 

LiYCY 3 x 0,50

Nexans ref. 10263238 - Country ref. 1005649

  • Packaging: Drum (1000m)
  • Approximate weight: 47 kg/km
  • Outer Diameter: 5.4 mm
  • Conductor cross-section: 0.5 mm²
  • Number of cores: 3

 

LiYCY 3 x 0,75

Nexans ref. 10568870 - Country ref. 1005666

  • Packaging: Drum (1000m)
  • Approximate weight: 59 kg/km
  • Outer Diameter: 6 mm
  • Conductor cross-section: 0.75 mm²
  • Number of cores: 3

 

LiYCY 4 x 0,50

Nexans ref. 10567413 - Country ref. 1005650

  • Packaging: Drum (1000m)
  • Approximate weight: 55 kg/km
  • Outer Diameter: 5.8 mm
  • Conductor cross-section: 0.5 mm²
  • Number of cores: 4

 

LiYCY 4 x 0,75

Nexans ref. 10567416 - Country ref. 1005667

  • Packaging: Drum (1000m)
  • Approximate weight: 71 kg/km
  • Outer Diameter: 6.5 mm
  • Conductor cross-section: 0.75 mm²
  • Number of cores: 4

 

LiYCY 5 x 0,50

Nexans ref. 10263240 - Country ref. 1005651

  • Packaging: Drum (1000m)
  • Approximate weight: 66 kg/km
  • Outer Diameter: 6.3 mm
  • Conductor cross-section: 0.5 mm²
  • Number of cores: 5

 

LiYCY 5 x 0,75

Nexans ref. 10263257 - Country ref. 1005668

  • Packaging: Drum (1000m)
  • Approximate weight: 86 kg/km
  • Outer Diameter: 7.1 mm
  • Conductor cross-section: 0.75 mm²
  • Number of cores: 5

 

LiYCY 7 x 0,50

Nexans ref. 10263241 - Country ref. 1005653

  • Packaging: Drum (1000m)
  • Approximate weight: 82 kg/km
  • Outer Diameter: 6.8 mm
  • Conductor cross-section: 0.5 mm²
  • Number of cores: 7

 

LiYCY 7 x 0,75

Nexans ref. 10263258 - Country ref. 1005670

  • Packaging: Drum (1000m)
  • Approximate weight: 108 kg/km
  • Outer Diameter: 7.7 mm
  • Conductor cross-section: 0.75 mm²
  • Number of cores: 7

 

LiYCY 8 x 0,50

Nexans ref. 10263242 - Country ref. 1005654

  • Packaging: Drum (1000m)
  • Approximate weight: 94 kg/km
  • Outer Diameter: 8.3 mm
  • Conductor cross-section: 0.5 mm²
  • Number of cores: 8

 

LiYCY 8 x 0,75

Nexans ref. 10263259 - Country ref. 1005671

  • Packaging: Drum (1000m)
  • Approximate weight: 117 kg/km
  • Outer Diameter: 8.7 mm
  • Conductor cross-section: 0.75 mm²
  • Number of cores: 8

 

Description

Description

Standards

  • Product
    IEC 60228
  • Test
    IEC 60332-1-2

LiYCY 300/500 V is a flexible shielded signal cable that is widely used in control systems. LiYCY 300/500 V is a natural choice for signaling-, Instrumentation-, process and facility systems. The cable is primarily designed for indoor use, but can be used outdoors with extra protection. The conductors are color-coded according to DIN 47100. LiYCY 300/500 V can be supplied as a halogen free cable, it is then called LiHCH.


Technical Data

  • Operating Voltage   

0.22 mm² - 0.34 mm²  250 V 

≥0.50 mm2 300/500 V

  • Test Voltage 

0.22 ve 0.34 mm²  1200 V 

​≥0.50 mm² 2000 V

  •  Insulation Res.: > 200 MΩ km
  •  Temperature Range: -20°C … + 70°C
  •  Temperature Range Flexible: -5°C … + 70°C
  •  Min. Bending Radius: 10 x Overall Diameter


Construction

  • Class 5 copper conductors according to IEC 60228
  • PVC insulation, with colour coding according to DIN47100
  • Polyester tape wrapping
  • Tinned copper wire braiding; coverage 70%±3%
  • PVC outer sheath, RAL7001 Grey Colour
  • Reference Standards: VDE 0814 and VDE0812
  • Outer Sheath is UV protected, making the cable available for installations that requires this

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Armour type
Tinned copper braid
Conductor material
Bare copper class 5
Insulation
PVC-compound TI2
Outer sheath
PVC
Sheath colour
Grey RAL 7001

Electrical characteristics

Electrical characteristics

Resistance of the insulation
200 MOhm
Test voltage
2000 V

Usage characteristics

Usage characteristics

Packaging
Drum 1000 m
Minimum bending radius, static (XD)
10
Operating temperature flexing, range
- °C
Operating temperature, fixed, range
-20 ... 70 °C
RoHS compliant
Yes

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close