TSLF 72 - 170kV singel core

Products

TSLF 72 kV 1x150A

Nexans ref.

  • Packaging: Drum (m)
  • Conductor cross-section: 150 mm²
  • Conductor diameter: 14.1 mm
  • Diameter over insulation: 40.4 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 51.0 mm
  • Approximate weight: 2.3 kg/m
  • Maximum operating voltage: 72 kV
  • Rated Voltage Uo/U (Um): 36/66 (72,5) kV
  • Bending factor when installed: - (xD)

 

TSLF 72kV 1x240A

Nexans ref. 10132941 - Country ref. 1007559

  • Packaging: Drum (m)
  • Conductor cross-section: 240 mm²
  • Conductor diameter: 18.2 mm
  • Diameter over insulation: 44.5 mm
  • Earth conductor cross section: 35 mm²
  • Nominal outer diameter: 55.2 mm
  • Approximate weight: 2.76 kg/m
  • Maximum operating voltage: 72 kV
  • Rated Voltage Uo/U (Um): 36/66 (72,5) kV
  • Bending factor when installed: - (xD)

 

TSLF 72 kV 1x240A 14 mm insulation

Nexans ref. 10239174

  • Packaging: Drum (m)
  • Conductor cross-section: 240 mm²
  • Conductor diameter: 18.2 mm
  • Diameter over insulation: 48.5 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 60.0 mm
  • Approximate weight: 3.17 kg/m
  • Maximum operating voltage: 72 kV
  • Rated Voltage Uo/U (Um): 36/66 (72,5) kV
  • Bending factor when installed: - (xD)

 

TSLF 72 kV 1x400A

Nexans ref. 10094413

  • Packaging: Drum (m)
  • Conductor cross-section: 400 mm²
  • Conductor diameter: 23.6 mm
  • Diameter over insulation: 49.9 mm
  • Earth conductor cross section: 35 mm²
  • Nominal outer diameter: 61.0 mm
  • Approximate weight: 3.5 kg/m
  • Maximum operating voltage: 72 kV
  • Rated Voltage Uo/U (Um): 36/66 (72,5) kV
  • Bending factor when installed: 10 (xD)

 

TSLF 72 kV 1x400A 14 mm insulation

Nexans ref. 10572548

  • Packaging: Drum (m)
  • Conductor cross-section: 400 mm²
  • Conductor diameter: 23.6 mm
  • Diameter over insulation: 53.9 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 65.0 mm
  • Approximate weight: 3.8 kg/m
  • Maximum operating voltage: 72 kV
  • Rated Voltage Uo/U (Um): 36/66 (72,5) kV
  • Bending factor when installed: - (xD)

 

TSLF 72 kV 1x630A

Nexans ref. 10216095

  • Packaging: Drum (m)
  • Conductor cross-section: 630 mm²
  • Conductor diameter: 30.4 mm
  • Diameter over insulation: 56.7 mm
  • Earth conductor cross section: 50 mm²
  • Nominal outer diameter: 69.0 mm
  • Approximate weight: 4.64 kg/m
  • Maximum operating voltage: 72 kV
  • Rated Voltage Uo/U (Um): 36/66 (72,5) kV
  • Bending factor when installed: - (xD)

 

TSLF 72 kV 1x800A

Nexans ref.

  • Packaging: Drum (m)
  • Conductor cross-section: 800 mm²
  • Conductor diameter: 34.7 mm
  • Diameter over insulation: 61.5 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 74.0 mm
  • Approximate weight: 5.56 kg/m
  • Maximum operating voltage: 72 kV
  • Rated Voltage Uo/U (Um): 36/66 (72,5) kV
  • Bending factor when installed: - (xD)

 

TSLF 72 kV 1x800A 11mm isol

Nexans ref.

  • Packaging: Drum (m)
  • Conductor cross-section: 800 mm²
  • Conductor diameter: 34.7 mm
  • Diameter over insulation: 59.5 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 72.0 mm
  • Approximate weight: 5.4 kg/m
  • Maximum operating voltage: 72 kV
  • Rated Voltage Uo/U (Um): 36/66 (72,5) kV
  • Bending factor when installed: - (xD)

 

TSLF 72 kV 1x1000A

Nexans ref.

  • Packaging: Drum (m)
  • Conductor cross-section: 1000 mm²
  • Conductor diameter: 38.7 mm
  • Diameter over insulation: 65.5 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 78.0 mm
  • Approximate weight: 6.39 kg/m
  • Maximum operating voltage: 72 kV
  • Rated Voltage Uo/U (Um): 36/66 (72,5) kV
  • Bending factor when installed: - (xD)

 

TSLF 72 kV 1x1000A (15 mm isol)

Nexans ref.

  • Packaging: Drum (m)
  • Conductor cross-section: 1000 mm²
  • Conductor diameter: 38.7 mm
  • Diameter over insulation: 71.6 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 75.0 mm
  • Approximate weight: 6.9 kg/m
  • Maximum operating voltage: 72 kV
  • Rated Voltage Uo/U (Um): 36/66 (72,5) kV
  • Bending factor when installed: - (xD)

 

TSLF 72 kV 1x1200A

Nexans ref. 10196295

  • Packaging: Drum (m)
  • Conductor cross-section: 1200 mm²
  • Conductor diameter: 41.7 mm
  • Diameter over insulation: 68.5 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 81.0 mm
  • Approximate weight: 7.03 kg/m
  • Maximum operating voltage: 72 kV
  • Rated Voltage Uo/U (Um): 36/66 (72,5) kV
  • Bending factor when installed: - (xD)

 

TSLF 72 kV 1x1200A (14 mm isol og 30 mm² skjerm)

Nexans ref.

  • Packaging: Drum (m)
  • Conductor cross-section: 1200 mm²
  • Conductor diameter: 41.7 mm
  • Diameter over insulation: 72.5 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 85.0 mm
  • Approximate weight: 7.34 kg/m
  • Maximum operating voltage: 72 kV
  • Rated Voltage Uo/U (Um): 36/66 (72,5) kV
  • Bending factor when installed: - (xD)

 

TSLF 72 kV 1x1200A 12 mm isol og 95 mm² skjerm

Nexans ref.

  • Packaging: Drum (m)
  • Conductor cross-section: 1200 mm²
  • Conductor diameter: 41.7 mm
  • Diameter over insulation: 68.5 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 81.0 mm
  • Approximate weight: 7.5 kg/m
  • Maximum operating voltage: 72 kV
  • Rated Voltage Uo/U (Um): 36/66 (72,5) kV
  • Bending factor when installed: - (xD)

 

TSLF 170 kV 1x400A

Nexans ref. 10557321

  • Packaging: Drum (m)
  • Conductor cross-section: 400 mm²
  • Conductor diameter: 23.6 mm
  • Diameter over insulation: 62.4 mm
  • Earth conductor cross section: 95 mm²
  • Nominal outer diameter: 76.0 mm
  • Approximate weight: 5.1 kg/m
  • Maximum operating voltage: 170 kV
  • Rated Voltage Uo/U (Um): 87/150 (170) kV
  • Bending factor when installed: 10 (xD)

 

TSLF 170 kV 1x630A

Nexans ref. 10267694

  • Packaging: Drum (m)
  • Conductor cross-section: 630 mm²
  • Conductor diameter: 30.4 mm
  • Diameter over insulation: 67.2 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 81.0 mm
  • Approximate weight: 6.15 kg/m
  • Maximum operating voltage: 170 kV
  • Rated Voltage Uo/U (Um): 87/150 (170) kV
  • Bending factor when installed: - (xD)

 

TSLF 170 kV 1x800A

Nexans ref. 10260708

  • Packaging: Drum (m)
  • Conductor cross-section: 800 mm²
  • Conductor diameter: 34.7 mm
  • Diameter over insulation: 71.5 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 85.0 mm
  • Approximate weight: 6.87 kg/m
  • Maximum operating voltage: 170 kV
  • Rated Voltage Uo/U (Um): 87/150 (170) kV
  • Bending factor when installed: - (xD)

 

TSLF 170 kV 1x1000A

Nexans ref.

  • Packaging: Drum (m)
  • Conductor cross-section: 1000 mm²
  • Conductor diameter: 38.7 mm
  • Diameter over insulation: 76.0 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 90.0 mm
  • Approximate weight: 7.82 kg/m
  • Maximum operating voltage: 170 kV
  • Rated Voltage Uo/U (Um): 87/150 (170) kV
  • Bending factor when installed: - (xD)

 

TSLF 170 kV 1x1200A

Nexans ref. 10210291

  • Packaging: Drum (m)
  • Conductor cross-section: 1200 mm²
  • Conductor diameter: 41.7 mm
  • Diameter over insulation: 79.0 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 93.0 mm
  • Approximate weight: 8.55 kg/m
  • Maximum operating voltage: 170 kV
  • Rated Voltage Uo/U (Um): 87/150 (170) kV
  • Bending factor when installed: - (xD)

 

TSLF 170 kV 1x1600A

Nexans ref. 10215094

  • Packaging: Drum (m)
  • Conductor cross-section: 1600 mm²
  • Conductor diameter: 48.6 mm
  • Diameter over insulation: 85.9 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 101.0 mm
  • Approximate weight: 10.3 kg/m
  • Maximum operating voltage: 170 kV
  • Rated Voltage Uo/U (Um): 87/150 (170) kV
  • Bending factor when installed: - (xD)

 

TSLF 170 kV 1x2000A

Nexans ref.

  • Packaging: Drum (m)
  • Conductor cross-section: 2000 mm²
  • Conductor diameter: 57.2 mm
  • Diameter over insulation: 94.5 mm
  • Earth conductor cross section: - mm²
  • Nominal outer diameter: 110.0 mm
  • Approximate weight: 12.5 kg/m
  • Maximum operating voltage: 170 kV
  • Rated Voltage Uo/U (Um): 87/150 (170) kV
  • Bending factor when installed: - (xD)

 

Description

Description

Standards

  • Test
    IEC 60840

User benefits:

Diffusion free high voltage cable

Avoids growth of watertrees in the XLPE insulation and increases the lifetime of the cable.

Sheath integrity may be tested while on drum, before backfilling, in plastic pipes etc.

Meter marks

Screen section: Value given is the physical cross section of the copper wires in the screen.

Usage: Indoor, Underground, Outdoors

Intended for high voltage energy distribution

Fire properties:

Halogenfree
Cable marking:

NEXANS NS TSLF  kV 1 x mm²/mm² MONTH YEAR, metermarks

Lifemark

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Conductor shape
Circular compacted
Material of the inner semi-conductor
Extruded
Insulation
Extruded XLPE compound
Material of the external semi-conductor
Extruded
Screen
Copper wire
Radial waterproof
Yes
Conductor flexibility
Stranded class 2

Dimensional characteristics

Dimensional characteristics

Number of cores
1

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close