WATERLINK - TXRA 24kV

Products

TXRA 24 kV 3x 25 mm²

Nexans ref. 10543369 - Country ref. 1008060

  • Packaging: Cut to length (m)
  • Conductor diameter: 6.0 mm
  • Diameter over insulation: 18.5 mm
  • Nominal outer diameter: 61.1 mm
  • Approximate weight: 6400 kg/km
  • Conductor cross-section: 25 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24 kV 3x 25 mm² + GS48

Nexans ref. 10543368 - Country ref. 1008061

  • Packaging: Cut to length (m)
  • Conductor diameter: 6.0 mm
  • Diameter over insulation: 18.5 mm
  • Nominal outer diameter: 61.1 mm
  • Approximate weight: 6400 kg/km
  • Conductor cross-section: 25 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24 kV 3x 25 mm² + GS48 Zn

Nexans ref. 10260833 - Country ref. 1008064

  • Packaging: Cut to length (m)
  • Conductor diameter: 6.0 mm
  • Diameter over insulation: 18.5 mm
  • Nominal outer diameter: 61.1 mm
  • Approximate weight: 6400 kg/km
  • Conductor cross-section: 25 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24 kV 3x 25 mm² Zn

Nexans ref. 10265179 - Country ref. 1008063

  • Packaging: Cut to length (m)
  • Conductor diameter: 6.0 mm
  • Diameter over insulation: 18.5 mm
  • Nominal outer diameter: 61.1 mm
  • Approximate weight: 6400 kg/km
  • Conductor cross-section: 25 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24kV 3x50mm2+Gs(48) R3.2 Zn

Nexans ref. 10569291 - Country ref. 1008071

  • Packaging: Cut to length (m)
  • Conductor diameter: 8.2 mm
  • Diameter over insulation: 24.5 mm
  • Nominal outer diameter: 67.6 mm
  • Approximate weight: 6100 kg/km
  • Conductor cross-section: 50 mm²
  • Maximum pulling force by laying: 110 kN

 

TXRA 24 kV 3x 50 mm²

Nexans ref. 10551155 - Country ref. 1008066

  • Packaging: Cut to length (m)
  • Conductor diameter: 8.2 mm
  • Diameter over insulation: 20.1 mm
  • Nominal outer diameter: 68.2 mm
  • Approximate weight: 7700 kg/km
  • Conductor cross-section: 50 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24 kV 3x 50 mm² + GS48

Nexans ref. 10551279 - Country ref. 1008067

  • Packaging: Cut to length (m)
  • Conductor diameter: 8.2 mm
  • Diameter over insulation: 20.1 mm
  • Nominal outer diameter: 68.2 mm
  • Approximate weight: 7700 kg/km
  • Conductor cross-section: 50 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24 kV 3x 50mm² R4,2 Zn

Nexans ref. 10563034 - Country ref. 1008069

  • Packaging: Cut to length (m)
  • Conductor diameter: 8.2 mm
  • Diameter over insulation: 20.1 mm
  • Nominal outer diameter: 68.2 mm
  • Approximate weight: 7700 kg/km
  • Conductor cross-section: 50 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24kV 3x50mm2+Gs(48) Zn

Nexans ref. 10262743 - Country ref. 1008070

  • Packaging: Cut to length (m)
  • Conductor diameter: 8.2 mm
  • Diameter over insulation: 20.1 mm
  • Nominal outer diameter: 68.2 mm
  • Approximate weight: 7700 kg/km
  • Conductor cross-section: 50 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24 kV 3x 95 mm² + GS48

Nexans ref. 10538283 - Country ref. 1008073

  • Packaging: Cut to length (m)
  • Conductor diameter: 11.5 mm
  • Diameter over insulation: 23.4 mm
  • Nominal outer diameter: 76.7 mm
  • Approximate weight: 9900 kg/km
  • Conductor cross-section: 95 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24 kV 3x 95 mm² + GS48 Zn

Nexans ref. 10265176 - Country ref. 1008076

  • Packaging: Cut to length (m)
  • Conductor diameter: 11.5 mm
  • Diameter over insulation: 23.4 mm
  • Nominal outer diameter: 76.7 mm
  • Approximate weight: 9900 kg/km
  • Conductor cross-section: 95 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24 kV 3x 95 mm² + GS96 Zn

Nexans ref. 10539469 - Country ref. 1008077

  • Packaging: Cut to length (m)
  • Conductor diameter: 11.5 mm
  • Diameter over insulation: 23.4 mm
  • Nominal outer diameter: 76.7 mm
  • Approximate weight: 9900 kg/km
  • Conductor cross-section: 95 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24 kV 3x150 mm²

Nexans ref. 10545307 - Country ref. 1008080

  • Packaging: Cut to length (m)
  • Conductor diameter: 14.3 mm
  • Diameter over insulation: 26.2 mm
  • Nominal outer diameter: 79.5 mm
  • Approximate weight: 11940 kg/km
  • Conductor cross-section: 150 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24 kV 3x150 mm² + GS48 Zn

Nexans ref. 10560082 - Country ref. 1008082

  • Packaging: Cut to length (m)
  • Conductor diameter: 14.3 mm
  • Diameter over insulation: 26.2 mm
  • Nominal outer diameter: 79.5 mm
  • Approximate weight: 12500 kg/km
  • Conductor cross-section: 150 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24 kV 3x240 mm²

Nexans ref. 10562297 - Country ref. 1008084

  • Packaging: Cut to length (m)
  • Conductor diameter: 18.4 mm
  • Diameter over insulation: 30.3 mm
  • Nominal outer diameter: 88.1 mm
  • Approximate weight: 16000 kg/km
  • Conductor cross-section: 240 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24 kV 3x240 mm² + 2xGS48 Zn

Nexans ref. 10558911 - Country ref. 1008089

  • Packaging: Cut to length (m)
  • Conductor diameter: 18.4 mm
  • Diameter over insulation: 30.3 mm
  • Nominal outer diameter: 88.1 mm
  • Approximate weight: 16000 kg/km
  • Conductor cross-section: 240 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24 kV 3x240 mm² + GS48 Zn

Nexans ref. 10262661 - Country ref. 1008088

  • Packaging: Cut to length (m)
  • Conductor diameter: 18.4 mm
  • Diameter over insulation: 30.3 mm
  • Nominal outer diameter: 88.1 mm
  • Approximate weight: 16000 kg/km
  • Conductor cross-section: 240 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24 kV 3x240mm² R4,2 Zn

Nexans ref. 10563033 - Country ref. 1008087

  • Packaging: Cut to length (m)
  • Conductor diameter: 18.4 mm
  • Diameter over insulation: 30.3 mm
  • Nominal outer diameter: 88.1 mm
  • Approximate weight: 16000 kg/km
  • Conductor cross-section: 240 mm²
  • Maximum pulling force by laying: - kN

 

TXRA 24 kV 3x400 mm² + GS48 Zn

Nexans ref. 10558912 - Country ref. 1008095

  • Packaging: Cut to length (m)
  • Conductor diameter: 23.5 mm
  • Diameter over insulation: 38.2 mm
  • Nominal outer diameter: 98.0 mm
  • Approximate weight: 22000 kg/km
  • Conductor cross-section: 400 mm²
  • Maximum pulling force by laying: - kN

 

Description

Description

Standards

  • International
    IEC 60228; IEC 60502-2; Nexans specification

Armored PEX insulated submarine cables for utilities.

 

Construction:
 

Conductor:
Round multiple wire, compressed copper conductor

Conductor screen:
Extruded layer of semi-conductive cross-linked polyethylene.

Insulation:
Extruded insulation of cross-linked polyethylene.

Insulation screen:

Extruded insulation of cross-linked polyethylene.

Twisting and bonding:
Three insulated conductors are twisted together and bonded with semiconducting bands.
Fillers are installed in the winding rooms.
If desired, fiber cables can also be inserted into the winding rooms.

Armouring:
A layer of galvanized steel wires.
Zinc wires can be inserted into the reinforcement if desired.

Outer corrosion protection:
Two layers of polypropylene yarn with bitumen.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Stranded class 2

Dimensional characteristics

Dimensional characteristics

Number of cores
3

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
12 / 20 (24) kV

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close