WATERLINK - TXRA 24kV
WATERLINK - TXRA 24kV
Steel armored power submarine cables for utilities.
Read moreTXRA 24 kV 3x 25 mm²
Nexans ref. 10543369 - Country ref. 1008060
- Packaging: Cut to length (m)
- Conductor diameter: 6.0 mm
- Diameter over insulation: 18.5 mm
- Nominal outer diameter: 61.1 mm
- Approximate weight: 6400 kg/km
- Conductor cross-section: 25 mm²
- Maximum pulling force by laying: - kN
TXRA 24 kV 3x 25 mm² + GS48
Nexans ref. 10543368 - Country ref. 1008061
- Packaging: Cut to length (m)
- Conductor diameter: 6.0 mm
- Diameter over insulation: 18.5 mm
- Nominal outer diameter: 61.1 mm
- Approximate weight: 6400 kg/km
- Conductor cross-section: 25 mm²
- Maximum pulling force by laying: - kN
TXRA 24 kV 3x 25 mm² + GS48 Zn
Nexans ref. 10260833 - Country ref. 1008064
- Packaging: Cut to length (m)
- Conductor diameter: 6.0 mm
- Diameter over insulation: 18.5 mm
- Nominal outer diameter: 61.1 mm
- Approximate weight: 6400 kg/km
- Conductor cross-section: 25 mm²
- Maximum pulling force by laying: - kN
TXRA 24 kV 3x 25 mm² Zn
Nexans ref. 10265179 - Country ref. 1008063
- Packaging: Cut to length (m)
- Conductor diameter: 6.0 mm
- Diameter over insulation: 18.5 mm
- Nominal outer diameter: 61.1 mm
- Approximate weight: 6400 kg/km
- Conductor cross-section: 25 mm²
- Maximum pulling force by laying: - kN
TXRA 24kV 3x50mm2+Gs(48) R3.2 Zn
Nexans ref. 10569291 - Country ref. 1008071
- Packaging: Cut to length (m)
- Conductor diameter: 8.2 mm
- Diameter over insulation: 24.5 mm
- Nominal outer diameter: 67.6 mm
- Approximate weight: 6100 kg/km
- Conductor cross-section: 50 mm²
- Maximum pulling force by laying: 110 kN
TXRA 24 kV 3x 50 mm²
Nexans ref. 10551155 - Country ref. 1008066
- Packaging: Cut to length (m)
- Conductor diameter: 8.2 mm
- Diameter over insulation: 20.1 mm
- Nominal outer diameter: 68.2 mm
- Approximate weight: 7700 kg/km
- Conductor cross-section: 50 mm²
- Maximum pulling force by laying: - kN
TXRA 24 kV 3x 50 mm² + GS48
Nexans ref. 10551279 - Country ref. 1008067
- Packaging: Cut to length (m)
- Conductor diameter: 8.2 mm
- Diameter over insulation: 20.1 mm
- Nominal outer diameter: 68.2 mm
- Approximate weight: 7700 kg/km
- Conductor cross-section: 50 mm²
- Maximum pulling force by laying: - kN
TXRA 24 kV 3x 50mm² R4,2 Zn
Nexans ref. 10563034 - Country ref. 1008069
- Packaging: Cut to length (m)
- Conductor diameter: 8.2 mm
- Diameter over insulation: 20.1 mm
- Nominal outer diameter: 68.2 mm
- Approximate weight: 7700 kg/km
- Conductor cross-section: 50 mm²
- Maximum pulling force by laying: - kN
TXRA 24kV 3x50mm2+Gs(48) Zn
Nexans ref. 10262743 - Country ref. 1008070
- Packaging: Cut to length (m)
- Conductor diameter: 8.2 mm
- Diameter over insulation: 20.1 mm
- Nominal outer diameter: 68.2 mm
- Approximate weight: 7700 kg/km
- Conductor cross-section: 50 mm²
- Maximum pulling force by laying: - kN
TXRA 24 kV 3x 95 mm² + GS48
Nexans ref. 10538283 - Country ref. 1008073
- Packaging: Cut to length (m)
- Conductor diameter: 11.5 mm
- Diameter over insulation: 23.4 mm
- Nominal outer diameter: 76.7 mm
- Approximate weight: 9900 kg/km
- Conductor cross-section: 95 mm²
- Maximum pulling force by laying: - kN
TXRA 24 kV 3x 95 mm² + GS48 Zn
Nexans ref. 10265176 - Country ref. 1008076
- Packaging: Cut to length (m)
- Conductor diameter: 11.5 mm
- Diameter over insulation: 23.4 mm
- Nominal outer diameter: 76.7 mm
- Approximate weight: 9900 kg/km
- Conductor cross-section: 95 mm²
- Maximum pulling force by laying: - kN
TXRA 24 kV 3x 95 mm² + GS96 Zn
Nexans ref. 10539469 - Country ref. 1008077
- Packaging: Cut to length (m)
- Conductor diameter: 11.5 mm
- Diameter over insulation: 23.4 mm
- Nominal outer diameter: 76.7 mm
- Approximate weight: 9900 kg/km
- Conductor cross-section: 95 mm²
- Maximum pulling force by laying: - kN
TXRA 24 kV 3x150 mm²
Nexans ref. 10545307 - Country ref. 1008080
- Packaging: Cut to length (m)
- Conductor diameter: 14.3 mm
- Diameter over insulation: 26.2 mm
- Nominal outer diameter: 79.5 mm
- Approximate weight: 11940 kg/km
- Conductor cross-section: 150 mm²
- Maximum pulling force by laying: - kN
TXRA 24 kV 3x150 mm² + GS48 Zn
Nexans ref. 10560082 - Country ref. 1008082
- Packaging: Cut to length (m)
- Conductor diameter: 14.3 mm
- Diameter over insulation: 26.2 mm
- Nominal outer diameter: 79.5 mm
- Approximate weight: 12500 kg/km
- Conductor cross-section: 150 mm²
- Maximum pulling force by laying: - kN
TXRA 24 kV 3x240 mm²
Nexans ref. 10562297 - Country ref. 1008084
- Packaging: Cut to length (m)
- Conductor diameter: 18.4 mm
- Diameter over insulation: 30.3 mm
- Nominal outer diameter: 88.1 mm
- Approximate weight: 16000 kg/km
- Conductor cross-section: 240 mm²
- Maximum pulling force by laying: - kN
TXRA 24 kV 3x240 mm² + 2xGS48 Zn
Nexans ref. 10558911 - Country ref. 1008089
- Packaging: Cut to length (m)
- Conductor diameter: 18.4 mm
- Diameter over insulation: 30.3 mm
- Nominal outer diameter: 88.1 mm
- Approximate weight: 16000 kg/km
- Conductor cross-section: 240 mm²
- Maximum pulling force by laying: - kN
TXRA 24 kV 3x240 mm² + GS48 Zn
Nexans ref. 10262661 - Country ref. 1008088
- Packaging: Cut to length (m)
- Conductor diameter: 18.4 mm
- Diameter over insulation: 30.3 mm
- Nominal outer diameter: 88.1 mm
- Approximate weight: 16000 kg/km
- Conductor cross-section: 240 mm²
- Maximum pulling force by laying: - kN
TXRA 24 kV 3x240mm² R4,2 Zn
Nexans ref. 10563033 - Country ref. 1008087
- Packaging: Cut to length (m)
- Conductor diameter: 18.4 mm
- Diameter over insulation: 30.3 mm
- Nominal outer diameter: 88.1 mm
- Approximate weight: 16000 kg/km
- Conductor cross-section: 240 mm²
- Maximum pulling force by laying: - kN
TXRA 24 kV 3x400 mm² + GS48 Zn
Nexans ref. 10558912 - Country ref. 1008095
- Packaging: Cut to length (m)
- Conductor diameter: 23.5 mm
- Diameter over insulation: 38.2 mm
- Nominal outer diameter: 98.0 mm
- Approximate weight: 22000 kg/km
- Conductor cross-section: 400 mm²
- Maximum pulling force by laying: - kN
Description
Description
Standards
-
InternationalIEC 60228; IEC 60502-2; Nexans specification
Armored PEX insulated submarine cables for utilities.
Construction:
Conductor:
Round multiple wire, compressed copper conductor
Conductor screen:
Extruded layer of semi-conductive cross-linked polyethylene.
Insulation:
Extruded insulation of cross-linked polyethylene.
Insulation screen:
Extruded insulation of cross-linked polyethylene.
Twisting and bonding:
Three insulated conductors are twisted together and bonded with semiconducting bands.
Fillers are installed in the winding rooms.
If desired, fiber cables can also be inserted into the winding rooms.
Armouring:
A layer of galvanized steel wires.
Zinc wires can be inserted into the reinforcement if desired.
Outer corrosion protection:
Two layers of polypropylene yarn with bitumen.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania