MILLIMAT/150 HS 1500W 10,0 m²

Description

Description

Standards

  • Test
    EN 50265; IEC 60332-1
  • International
    IEC 60335-2-96

MILLIMAT® 150W/m² is ideal for both renovation and new building projects. The heating cable mat consists of a twin conductor heating cable attached to a thin adhesive flexible fibreglass net. Products marked with "HS" are delivered with a cold lead seamlessly integrated with the heating cable itself from the factory. Products without the "HS" marking come with a manual splice between the cold lead and the heating cable itself. 

IP-class, end seal : IPX7
Total mat thickness (incl. heating cable + net) : 4.5 mm

MILLIMAT® 150W/m² is recommended for bathrooms, toilets, laundry rooms and other areas requiring high output. The mat must be installed on a non-combustible subfloor, levelled and stable. The mat is designed to be embedded into concrete or screed. The floor covering must be non-combustible and can be tiles, stone, vinyl, etc. The heating cable mat is adjusted to the room shape by cutting the net. Please see installation instructions for further details.
 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Type of conductor
Resistance alloy, solid
Insulation
FEP
Drain wire
Solid tinned copper
Screen
Longitudinal aluminium tape + copper wire
Outer sheath
PVC
Type of splice
Intergrated/hidden
Number of conductors
2
Sheath colour
Blue

Dimensional characteristics

Dimensional characteristics

Mat length
20 m
Mat area
10 m²
Min room area
11.1 m²
Approximate net weight
7.0 kg
Mat width
0.5 m
Thickness
4.5 mm
Nominal outer diameter
4.0 mm

Electrical characteristics

Electrical characteristics

Max. element resistance
38.8 Ohm
Min. element resistance
33.5 Ohm
Nominal area output
150 W/m²
Nominal element resistance
35.3 Ohm
Nominal output
1500 W
Operating voltage
230 V

Usage characteristics

Usage characteristics

Element length
100 m
Length of cold lead
2.5 m
Output
15 W/m

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1000336-NOLA
  • Certification Date : 1/18/17
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 0402
  • Declared performance : Eca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close