PFSP 1kV with copper conductor (4x6 - 3x70 mm²)

Products

PFSP 1kV 4x6/6

Nexans ref. 10021726 - Country ref. 1067058

  • Packaging: Drum (999m)
  • Conductor shape: Circular
  • Conductor diameter: 2.7 mm
  • Nominal outer diameter: 17.8 mm
  • Number of cores: 4
  • Conductor cross-section: 6 mm²

 

PFSP 1kV 2x10/10

Nexans ref. 10021706 - Country ref. 1067048

  • Packaging: Drum (999m)
  • Conductor shape: Circular
  • Conductor diameter: 3.9 mm
  • Nominal outer diameter: 18.0 mm
  • Number of cores: 2
  • Conductor cross-section: 10 mm²

 

PFSP 1kV 3x10/10

Nexans ref. 10021712 - Country ref. 1067038

  • Packaging: Drum (999m)
  • Conductor shape: Circular
  • Conductor diameter: 3.9 mm
  • Nominal outer diameter: 18.6 mm
  • Number of cores: 3
  • Conductor cross-section: 10 mm²

 

PFSP 1kV 4x10/10

Nexans ref. 10021727 - Country ref. 1067045

  • Packaging: Drum (999m)
  • Conductor shape: Circular
  • Conductor diameter: 3.9 mm
  • Nominal outer diameter: 20.0 mm
  • Number of cores: 4
  • Conductor cross-section: 10 mm²

 

PFSP 1kV 2x16/16

Nexans ref. 10021707 - Country ref. 1067049

  • Packaging: Drum (999m)
  • Conductor shape: Circular
  • Conductor diameter: 4.8 mm
  • Nominal outer diameter: 20.0 mm
  • Number of cores: 2
  • Conductor cross-section: 16 mm²

 

PFSP 1kV 3x16/16

Nexans ref. 10021713 - Country ref. 1067039

  • Packaging: Drum (999m)
  • Conductor shape: Circular
  • Conductor diameter: 4.8 mm
  • Nominal outer diameter: 21.0 mm
  • Number of cores: 3
  • Conductor cross-section: 16 mm²

 

PFSP 1kV 4x16/16

Nexans ref. 10021728 - Country ref. 1067046

  • Packaging: Drum (999m)
  • Conductor shape: Circular
  • Conductor diameter: 4.8 mm
  • Nominal outer diameter: 23.1 mm
  • Number of cores: 4
  • Conductor cross-section: 16 mm²

 

PFSP 1kV 3x25/16

Nexans ref. 10021714 - Country ref. 1067044

  • Packaging: Drum (999m)
  • Conductor shape: Circular
  • Conductor diameter: 6.0 mm
  • Nominal outer diameter: 24.4 mm
  • Number of cores: 3
  • Conductor cross-section: 25 mm²

 

PFSP 1kV 4x25/16

Nexans ref. 10021729 - Country ref. 1067047

  • Packaging: Drum (999m)
  • Conductor shape: Circular
  • Conductor diameter: 6.0 mm
  • Nominal outer diameter: 26.6 mm
  • Number of cores: 4
  • Conductor cross-section: 25 mm²

 

PFSP 1kV 3x35/16

Nexans ref. 10021715 - Country ref. 1067050

  • Packaging: Drum (999m)
  • Conductor shape: Circular
  • Conductor diameter: 7.0 mm
  • Nominal outer diameter: 27.0 mm
  • Number of cores: 3
  • Conductor cross-section: 35 mm²

 

PFSP 1kV 3x50/25

Nexans ref. 10021716 - Country ref. 1067051

  • Packaging: Drum (999m)
  • Conductor shape: Sector-shaped
  • Conductor diameter: - mm
  • Nominal outer diameter: 27.4 mm
  • Number of cores: 3
  • Conductor cross-section: 50 mm²

 

PFSP 1kV 3x70/35

Nexans ref. 10021717 - Country ref. 1067052

  • Packaging: Drum (999m)
  • Conductor shape: Sector-shaped
  • Conductor diameter: - mm
  • Nominal outer diameter: 31.0 mm
  • Number of cores: 3
  • Conductor cross-section: 70 mm²

 

Description

Description

Standards

  • International
    EN 50265; HD 603.3J; IEC 60332-1

Recommended for indoor and outdoor use in all areas, and can be installed directly in the ground without extra protection. PFSP 1kV is suitable for all low voltage systems i.e 230V, 400V and 690V.

The copper screen is dimensioned to fulfill the requirements for earth conductor (PE) or combined earth- and neutral conductor (PEN). The copper screen is made of copper wires with a counter helix to ensure contact between the wires. 

If the cable is cut outdoor, any end(s) must be sealed if not connected/terminated. This to prevent water intrusion, and possible corrosion in the future.

Min. installation temperature without extra precautions: 0 °C

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Sheath colour
Grey
Conductor material
Bare annealed copper stranded
Core identification
Colours
Insulation
PVC
Lead free
Yes
Outer sheath
PVC

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Bending factor when laying
8 (xD)
Maximum operating temperature
70 °C
RoHS compliant
Yes

Resources

Resources

Current capacity table PVC insulation multicore single phase

PVC insulation/two loaded conductors, copper or aluminium –

Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in ground

Conductor cross-section
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
1.5 14.0 0.0 16.5 0.0 19.5 0.0 22.0 0.0 22.0 0.0 22.0 0.0
2.5 18.5 14.5 23.0 17.5 27.0 21.0 27.0 22.0 28.0 0.0 30.0 23.0
4.0 25.0 19.5 30.0 24.0 36.0 28.0 37.0 29.0 38.0 0.0 40.0 31.0
6.0 32.0 25.0 38.0 30.0 46.0 36.0 46.0 36.0 48.0 0.0 51.0 39.0
10.0 43.0 33.0 52.0 41.0 63.0 49.0 60.0 47.0 64.0 0.0 70.0 54.0
16.0 57.0 44.0 69.0 54.0 85.0 66.0 78.0 61.0 83.0 63.0 94.0 73.0
25.0 75.0 58.0 90.0 71.0 112.0 83.0 99.0 77.0 110.0 82.0 119.0 89.0
35.0 92.0 71.0 111.0 86.0 138.0 103.0 119.0 93.0 132.0 98.0 148.0 111.0
50.0 110.0 86.0 133.0 104.0 168.0 125.0 140.0 109.0 156.0 117.0 180.0 135.0
70.0 139.0 108.0 168.0 131.0 213.0 160.0 173.0 135.0 192.0 145.0 232.0 173.0
95.0 167.0 130.0 201.0 157.0 258.0 195.0 204.0 159.0 230.0 173.0 282.0 210.0
120.0 192.0 150.0 232.0 181.0 299.0 226.0 231.0 180.0 261.0 200.0 328.0 244.0
150.0 219.0 172.0 258.0 201.0 344.0 261.0 261.0 204.0 293.0 224.0 379.0 282.0
185.0 248.0 195.0 294.0 230.0 392.0 298.0 292.0 228.0 331.0 255.0 434.0 322.0
240.0 291.0 229.0 344.0 269.0 461.0 352.0 336.0 262.0 382.0 298.0 514.0 380.0
300.0 334.0 263.0 394.0 308.0 530.0 406.0 379.0 296.0 427.0 336.0 593.0 439.0
A2 Multi-core cable in conduit in a thermally insulated wall
B2 Multi-core cable in conduit on a wooden wall
C Single-core or multi-core cable on a wooden wall
D1 Single-core or Multi-core cable in ducts in the ground
D2 Single-core or Multi-core cables designed to be buried directly in the ground
E Multi-core cable in free air

Current capacity table PVC insulation multicore three phase

PVC insulation, three loaded conductors/copper or aluminium –

Conductor temperature: 70 °C, ambient temperature: 30 °C in air, 20 °C in ground

Conductor cross-section
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
1.5 13.0 0.0 15.0 0.0 17.5 0.0 18.0 0.0 19.0 0.0 18.5 0.0
2.5 17.5 13.5 20.0 15.5 24.0 18.5 24.0 18.5 24.0 0.0 25.0 19.5
4.0 23.0 17.5 27.0 21.0 32.0 25.0 30.0 24.0 33.0 0.0 34.0 26.0
6.0 29.0 23.0 34.0 27.0 41.0 32.0 38.0 30.0 41.0 0.0 43.0 33.0
10.0 39.0 31.0 46.0 36.0 57.0 44.0 50.0 39.0 54.0 0.0 60.0 46.0
16.0 52.0 41.0 62.0 48.0 76.0 59.0 64.0 50.0 70.0 53.0 80.0 61.0
25.0 68.0 53.0 80.0 62.0 96.0 73.0 82.0 64.0 92.0 69.0 101.0 78.0
35.0 83.0 65.0 99.0 77.0 119.0 90.0 98.0 77.0 110.0 83.0 126.0 96.0
50.0 99.0 78.0 118.0 92.0 144.0 110.0 116.0 91.0 130.0 99.0 153.0 117.0
70.0 125.0 98.0 149.0 116.0 184.0 140.0 143.0 112.0 162.0 122.0 196.0 150.0
95.0 150.0 118.0 179.0 139.0 223.0 170.0 169.0 132.0 193.0 148.0 238.0 183.0
120.0 172.0 135.0 206.0 160.0 259.0 197.0 192.0 150.0 220.0 169.0 276.0 212.0
150.0 196.0 155.0 225.0 176.0 299.0 227.0 217.0 169.0 246.0 189.0 319.0 245.0
185.0 223.0 176.0 255.0 199.0 341.0 259.0 243.0 190.0 278.0 214.0 364.0 280.0
240.0 261.0 207.0 297.0 232.0 403.0 305.0 280.0 218.0 320.0 250.0 430.0 330.0
300.0 298.0 237.0 339.0 265.0 464.0 351.0 316.0 247.0 359.0 282.0 497.0 381.0
A2 Multi-core cable in conduit in a thermally insulated wall
B2 Multi-core cable in conduit on a wooden wall
C Single-core or multi-core cable on a wooden wall
D1 Single-core or Multi-core cable in ducts in the ground
D2 Single-core or Multi-core cables designed to be buried directly in the ground
E Multi-core cable in free air

Selling & delivery Information

The cable is marked with LIFEMARK™

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close