Beskrivelse
Standarder
Internasjonal : EN 45545 - HL3; EN 50264-3-1; IEC 60228Beskrivelse
Applications
For protected installation in railway vehicles (locomotives, trains, trolley-busses etc.), switching station and control panels. Installation in cable ducts, pipes and tubes.
Current carrying capacity according to EN 50343 as well as VDE 0298 part 4.
Complies with performance requirements acc. to EN 45545-2 - HL3.
Design
1. Conductor
Flexible stranded tinned copper class 5 acc. to IEC 60228
Optional halogen-free separator tape
2. Insulation
Cross-linked compound type EI 109 acc. to EN 50264-3-1
Oil, diesel, ozone and UV resistant
Colour: black or optionally green/yellow or other colours
Cable marking
Printing white:
FLAMEX EN 50264-3-1 600V mm² M (N)HXAF 0,6/1kV I NEXANS I WW-YYYY
Egenskaper
Konstruksjonsegenskaper | |
---|---|
Halogenfri | EN 50267-2-1 & EN 60684-2 |
Kappefarge | Svart |
Leder fleksibilitet | Flexible stranded |
Ledermateriale | Fortinnet kobber |
Farge | Svart |
Dimensjonsegenskaper | |
Ledertverrsnitt | 10mm² |
Ytre diameter min. | 5,5mm |
Ytre diameter maks. | 5,9mm |
Vekt (ca.) | 102kg/km |
Elektriske egenskaper | |
Normert spenning i 3 fase systemer Uo/U | 0.6/ 1 (1.2) kV |
Bruksegenskaper | |
Driftstemperatur område | -40 .. 90°C |
Maks. tillatt ledertemperatur | 90°C |
Korrosive gasser | EN 50267-2-2 |
Irriterende avgasser | EN 50305-9.2 |
Flammehemmende | IEC 60332-1-2 |
Brannbegrensende | EN 60332-3-24 & EN 60332-3-25 |
Min. bøyeradius v/gjentatt bøying eller bearbeiding | 5(xD) |
Min. bøyeradius ferdig installert | 3(xD) |
Motstandsdyktighet i forhold til olje | Ja |
Motstandsdyktig mot Ozon | Ja |
Motstandsdyktighet mot UV | Ja |
Statisk driftstemperatur område | -40 .. 120°C |
Maks. ledertemperatur v/ kortslutning | 200°C |
Relevant informasjon
Electrical Properties
Nominal voltage |
Uo/U (Umax) = 0.6/1 (1.2) kV |
Max. operating voltage in DC installations, one-sided earthed |
Vo= 0.9 kV DC |
Testing AC voltage (5 minutes) |
U = 3.5 kV |
Maks kontinuerlig ledertemperatur
Ledertemperatur ved normal drift |
≤ 90 °C / 250.000 timer |
|
≤ 120 °C / 20.000 timer |
Ledertemperatur ved overbelastning |
≤ 160 °C / 50 timer |
Ledertemperatur ved kortslutning (fortinnet leder) |
≤ 200 °C |
Informasjon
Special conditions relating to temperature and bending radii (e.g. by compelled guidance into cluthes, wagon transition and boogies) on request.